Install Structure Component

Explanation

This activity is used to add a component that exists in the actual structure but not listed in the as-built structure, to the new as built structure. Since the component is already with the structure being repaired, material handling will not be necessary in this case.

Prerequisites

Multilevel repair shop order should exist with the parent part in the Reserved or Issued state.

System Effects

As a result of this activity, the installed component will be added to the new as-built structure once the repair shop order has been received.

Window

Shop Order

Related Window Descriptions

Component Replacement Details

Procedure

  1. Open the Shop Order window and query for your multilevel repair shop order.
  2. Make sure that the state of the parent material line is Reserved or Issued.
  3. Open the Multilevel Repair Structure tab.
  4. Select the top part from the graphical tree structure, right-click and then click Expand Descendents.
  5. Select the revision node of the parent part to which you want to install a component.
  6. Right-click and then click Component Replacement to open the Component Replacement Details dialog box with the parent part you selected in the header as the parent part.
  7. Click Add to create a new record in the table. Select Install from Repair Action field.
  8. In the field of Replace Part No, enter the part number you want to add. Here you can get the List of Values.
  9. Enter the actual values you found with the part to be installed in Serial No, Lot/Batch No, W/D/R/No, Revision No, in replacement part parameter fields.
  10. Enter the installed component quantity in the Replace Quantity field.
  11. Enter the repair reason for the structure changes. Here you can get the List of Values.
  12. Click Apply or OK.

Note: If the component you are installing is serial-tracked, then the quantity should be always 1. You may add multiple lines for each serial component.