Establish Maintenance Data for a Template Structure
Explanation
This activity is used to establish operational
parameters and Maintenance Group for the serial parts of a template structure. The different options available
in this activity are also
available as separate activities that operate on single serial parts. This
activity is useful when introducing a new type of material (i.e., new part revision,
new product and model) or when modifying existing template
structures.
The following options are available within this
activity:
- Create new operational parameters for several or all
the serial parts within a template structure.
- Create new Maintenance Group for several or all the
serial
parts within a template structure.
- Establish or modify certain data elements for
operational parameters per maintenance group. The data elements that can be
specified are the maximum value and all the average operational values.
Prerequisites
- Serial parts need to exist.
- The serial parts for which you want to establish data must exist in a
serial structure template.
- Basic data for the operational parameters must have been
defined.
- To create Maintenance Group for a template
structure, at least the primary operational parameter must have been defined for all
the serial parts in the structure.
- To establish or modify operational parameters per
maintenance group, the maintenance group needs to exist for the serial parts in
the structure.
System Effects
System effects of creating operational parameters are:
- For life limited parts, it is possible to define life limits for the
entered operational parameters.
- When adding new operational parameters, any maintenance
group defined for the part is updated with the new operational parameter.
- You can register operational log data for all of the
serials belonging to a registered part number and maintenance group.
System effects of creating Maintenance Group are:
-
Interval maintenance and maintenance plans can be
defined.
System effects of establishing or modifying operational
parameters per maintenance group are:
- You can register operational log data for all the serials belonging to a registered part number and maintenance group.
Window
Establish
Maintenance Data for Template Structures
Related Window Descriptions
Establish Maintenance Data for
Template Structures
Procedure
Use the following procedure to create an operational
parameter for serial parts within a template structure:
- Open the
Establish Maintenance Data for
Template Structures window and query (F3) for the template structure
you want to work with.
- In the Oper Param list, select an operational
parameter.
- Select the Primary Oper Param check box, if
the selected operational parameter is to be the primary operational
parameter. Furthermore, select either the Time Parameter or
Cycle Parameter check box depending on whether this is to be the operational parameter for times
or cycles.
- Right-click and then click Spread Suggested Data to Structure.
Suggested values are updated on all the serial parts in the structure.
- The table (on the
Template
Structure tab) displays
all the serial parts in the structure. You can modify the data for the selected operational parameter. For example, if one serial part
does not require the suggested values, you can manually remove
these values from the part.
- To save the changes, right-click and then click Save Operational Parameters for Parts. As a result, all the serial parts
in the structure with operational parameter data will receive the new
operational parameter. If Maintenance Group exist for any of the serial
parts, the new operational parameter value will be updated on these Maintenance Group.
Use the following procedure to create a maintenance
group for serial parts within a template structure:
- Open the
Establish Maintenance Data for
Template Structures window and query (F3) for the template structure
you want to work with.
- Enter an ID for the new maintenance group in
the Maint Group field. Enter a description for this maintenance group
in the Maint Group Description field.
- In the Average Value Rule list, select an
average value rule.
- Select the Preferred Maint Group check box,
if the new maintenance group is to be the preferred maintenance group.
- Right-click and then click Spread Suggested Data
to Structure. Suggested values are updated on all the serial parts in the
structure.
- The table (on the
Template
Structure tab) displays all the serial parts in the structure. You
can modify the data for the new maintenance group. For example, if the new maintenance
group is not the preferred maintenance group for a serial part, you can clear the Preferred Maint Group check box for the part.
- To save the changes, right-click and then click
Save Maintenance Group for Parts. As a result, all the serial parts in the
structure with maintenance group data will receive the new maintenance
group.
Use the following procedure to establish or modify
operational parameters per maintenance group for serial parts within a template
structure:
- Open the
Establish Maintenance Data for
Template Structures window and query (F3) for the template structure
you want to work with.
- In the Oper Param list, select an operational
parameter for which the data is to be updated.
- Enter relevant values in the Max Value,
Planned Average, Historical Average and Manual Average
fields.
- Right-click and then click Spread Suggested Data to Structure.
Suggested values are updated on all serial parts in the structure.
- The table (on the Template Structure
tab) displays all the serial parts in the structure. You can modify data for the operational parameter per maintenance group
settings. For example, if the suggested data is not relevant for one serial
part, these values can be manually removed from the part.
- To save the changes, right-click and then click Save Modified Operational Parameter Values.
As a result, all the Maintenance Group for all the serial parts in the structure
with operational parameter settings is updated. Note: Only Maintenance Group that have existing operational parameters will be
updated.
Use the following procedure if the data to be
established or modified applies to all serials in the structure and does not
need to be adjusted on certain parts:
- Open the
Establish Maintenance Data for
Template Structures window and query (F3) for the template structure
you want to work with.
- If an operational parameter is to be created,
select an operational parameter from the Oper Param list.
- Select the Primary Oper Param check box, if
the selected operational parameter is to be the primary operational
parameter. Furthermore, select either the Time Parameter or
Cycle Parameter check box depending on whether this is to be the operational parameter for times
or cycles.
- If a maintenance group is to be created, enter
appropriate values in the Maint Group, Maint Group Description
and Average Value Rule fields.
- Select the Preferred Maint Group check box
if the maintenance group is to be the preferred maintenance group.
- If you need to adjust operational parameter
settings per maintenance group, specify valid values in the Max Value,
Planned Average, Historical Average, and Manual Average
fields.
- Right-click and then click Spread and Save Suggested
Data to Structure. As a result,
- All the serial parts in the template structure
will receive the new operational parameter or the new maintenance
group.
- All the Maintenance Group for the serial
parts in the structure that have operational parameter values will
be updated.
Note: If by accident you select or type an incorrect value, and then add the value on all
the parts in the table through the Spread Suggested Data to Structure
option, simply select or type the correct value and use Spread Suggested Data to Structure
option again to update the table.