Set Serial Structure Out Of Operation
Explanation
This activity is used to set the operational status for 
the selected serial and all serials below it in the structure to Out Of 
Operation. You can use this activity during the following instances:
	- when you build a serial structure and want to set 
	its operational status from Planned For Operation to Out Of 
	Operation for the first time
- if there are some serials in the serial structure 
	that have the Out Of Operation status whilst the other serials do not
When the structure is In Operation the 
operational condition of all serials in the structure will be Operational. 
Once the operational status of the structure is changed from In Operation 
to Out Of Operation, you can change the operational condition of all 
serials in the structure to Non Operational.
When building a new serial structure, the operational status is initially set 
to Planned For Operation and the operational condition to Non 
Operational. If the serials are not new (but new within the system), the 
serial's history data must be entered in the  
Component Life 
window. To do this, the serials must be in the Out Of Operation status. 
When the serials are set to Out Of Operation, default values are created 
for the operational log and interval maintenance. The serials are assigned to 
modifications if the serials are within a defined serial range or if the serials 
have a part number which is assigned to the modification.
If the operational status is changed from Planned For Operation to 
Out Of Operation while the Set Structure Operational check box is 
selected, the structure is verified and validations are performed (these are the 
same validations that are performed when a structure is set to In Operation). 
Once the operational condition of the serials is set to Operational, the 
structure is complete. You are highly recommended to verify the new total 
operational values and other information entered in the Component Life 
window.
Functional options for resetting serial structure properties, for the 
selected serial and all serials below in the structure, are available in the 
Serial Structure Information/General tab. When changing the operational 
status of a serial in the General tab, it will be possible to 
change the condition code of the serial if the Condition Code functionality is 
enabled for the part number in IFS/Part Catalog.
Prerequisites
	- The Set Structure Out Of Operation option is enabled only
    if the operational status of the serial is set to a
        value other than Out Of Operation.
System Effects
  - The operational status for the selected serial and all
    the serials in
    its structure is set to Out Of Operation status.
- If the current operational status of the
        serial is Planned For Operation when you change it to Out
    of Operation, you are prompted to enter a
        structure change date that is used to create an entry in the
        replacement history if the serial is installed in a structure. This creates an entry in the
        replacement history for all of the serials in the structure in addition to the serial you have
    selected.
- If the operational status is
changed from Planned For Operation to Out Of Operation and Set Structure Operational is selected, all serials
    receive the operational condition Operational if the structure is validated and found to
    be acceptable.
Window
Serial
Structure Information
Component
Life
Related Window Descriptions
Serial
Structure Information
Serial
Structure Information/General
Serial
Structure Information/Consist Of
Serial
Structure Information/Multilevel
Component
Life
Procedure
Follow one of these procedures to change the operational status of a serial from
the Serial Structure Information  window:
Serial has an operational status of In Operation
	- Open the  
	Serial Structure Information window and query (F3) for 
	the necessary serial.
- Right-click anywhere in the header of the window (or anywhere in the  
	General tab), and then click Set Structure Out of Operation.
	
- A message appears requiring confirmation of the status change. Click 
	Yes to change the operational status to Out of Operation.
Follow this procedure to change the operational status of a serial and it's 
structure from Planned for Operation to Out of Operation:
  - Query (F3) for a serial that you want to set  Out 
	Of Operation.
- Right-click anywhere in the header of the window (or
    anywhere in the General  tab) and click Set Structure Out Of Operation
    to open the Set Serial Out of Operation dialog box (see Set Serial Out of
    Operation). 
- Enter a
        structure change date used to create an entry in the
        replacement history if the serial is installed in a structure. This creates an entry in the
        replacement history for all the serials in the structure and the serial you have
    selected. 
- Click OK to change the operational status to Out Of Operation.
Follow this procedure to set the operational status of a serial to Out of 
Operation:
	- Open the 
	Serial Structure Information window and query (F3) for 
	the necessary serial.
- Click the  
	General 
	tab.
- Right-click, point to Status, and then click Out of Operation. 
	The 
	Set Serial to be Out of Operation dialog box opens.
- Select the Set the serial to be Non Operational check box if you 
	want to change the operational condition of the serial to Non Operational
	at the same time that you are setting the serial out of operation.
- Click OK.
- If the  Condition Code check box is selected for the serial's 
	part number in IFS/Part Catalog, the 
	 Change Condition Code 
    dialog box opens. This dialog box is used to change the condition code of the serial part.