Create Serial Structure Template —Key Exercises
Note: Throughout this document, please replace any occurrences of XX
with your initials, group ID, user ID or other unique prefix, in order to
separate your training data from that of other students.
Main Exercises
Purpose: The purpose of this lesson is to create a
template structure for a Engine, Jet turbine using the part revisions
that you have created in previous exercises.
Windows:
Serial Structure Template
- Open the
Serial Structure Template window.
- Create a New Record and in Template Part Number field, enter
XX_ENG.
- Ensure that fields Part Rev., Template Part No., and
Template Rev. get updated with values *, XX_ENG, and * respectively.
- Click the
General tab and in the Catalog Number
field, enter XX_ENG.
- Clear the Allow non-unique
catalog numbers check box and save.
- Click the
Consist Of tab and create
a new record.
- In the field Part No., enter XX_A.
- Clear the Configured in Seperate Template check box.
- Select the Minimum Configuration check box.
- In the field Catalog Number, enter XX_A and save the record.
- Repeat steps 7 to 10 for Parts XX_B and XX_C.
This completes the 1st level of the
structure, and you are ready to define level 2.
- Select the Row which contains XX_A. Right click and then click Next
Level.
- Click the
Consist Of tab and create
a new records for component parts XX_A1 and XX_A2 and save.
This completes the 2nd level of the
structure, and you are ready to define level 3.
- Select the Row which contains XX_A1. Right click and then click Next
Level.
- Click the
Consist Of tab and create
a new records for component parts XX_A1, XX_A2 and XX_A3 and save.
Exceptions: For XX_A11, set
Quantity equals 4. Do not set XX_A12 as part of the minimum configuration.
You can find the
details in the following table.
Part No |
Configured in Separate
Template |
Minimum Configuration |
Quantity |
Catalog Number |
XX_ENG |
No |
Yes |
1 |
XX_ENG |
XX_A |
No |
Yes |
1 |
XX_A |
XX_B |
No |
Yes |
1 |
XX_B |
XX_C |
No |
Yes |
1 |
XX_C |
XX_A1 |
No |
Yes |
1 |
XX_A1 |
XX_A2 |
No |
Yes |
1 |
XX_A2 |
XX_A11 |
No |
Yes |
4 |
XX_A11 |
XX_A12 |
No |
No |
1 |
XX_A12 |
XX_A13 |
No |
Yes |
1 |
XX_A13 |
Purpose: The purpose of this exercise is to define
alternate parts that can be used in a structure.
Windows:
Serial Structure Template
Serial Structure Template/Alternates/Template Alternates
- Open the
Serial Structure Template window.
- Query for Part Number and Template Part Number XX_ENG.
- Click the
Alternates/Template Alternates tab and create a
new record.
- In the Installed Part Number field, enter XX_C.
- In the Installed Part Revision field, enter *.
- In the Interchangeability Code field, enter 2.
- In the Alternate Part Number field, enter XX_C_ALT1.
- In the Alternate Part Revision field, enter *.
- Save the Record.
Purpose: As the template structure of Engine, Jet turbine is
now
complete, you are ready to set the structure template to Active.
Windows:
Serial Structure Template
- Open the
Serial
Structure Template window
- Query for your XX_ENG Engine.
- Right-click in the window header, point to Status,
and then click Set Active. Note: This operation is irreversible.
- Click the
General tab and verify that the State field
displays Active.
- Your template structure is now ready to build serial structure upon.
Purpose: The purpose of this exercise is to show how to
define stress ratings for the template for the Engine, Jet turbine. In this
example, we will define two stress ratings: High and Low.
Windows:
Stress Ratings
- Open the Stress Ratings window.
- Create a new record, and in the field Stress Rating Template Part No,
enter XX_ENG.
- In the field Stress Rating Template Part Rev., enter *.
- In the field Stress Rating ID, enter XX_HIGH.
- In the field Stress Rating Description, enter High - Arctic
Climate and save the record.
- Create another record for the same template part where XX_LOW as the
Stress Rating ID and Low - Europe as the Stress Rating Description.
Save the record.
- Select the Record with Stress Rating ID XX_HIGH. Right click and
then click Set Default. This action will set XX_HIGH as the default
stress rating for the Template part No. XX_ENG.
Purpose: The purpose of this exercise is to show you how
to define life limits for the created rim part.
Windows:
Serial Part Revision
- Open the
Serial Part Revision window.
- Query for the part number XX_B, Rev *.
- Click the
Life Limit tab and enter 100 in the
Forewarning Days field.
- Save the record.
- Enter 100 as the Forewarning Days for parts XX_A11 and XX_A12 in
similar way.
- Query for the part number XX_B, Rev *.
- Right-click and then click Get Stress Ratings.
- Stress rating IDs are retrieved for all the template parts where the
Module B is included.
- Select the Record with XX_HIGH as the Stress Rating ID from
Templates table.
-
Enter 1000 as the value for field Life Limit in
Life Limits table.
-
Similarly, Enter Life Limit values according to
the following table.
Part Number |
Stress Rating |
Life Limit |
XX_B |
XX_HIGH |
1000 |
XX_B |
XX_LOW |
2000 |
XX_A11 |
XX_HIGH |
5000 |
XX_A11 |
XX_LOW |
10000 |
XX_A12 |
XX_HIGH |
1200 |
XX_A12 |
XX_LOW |
2400 |