Connect Maintenance Program to Serial

Explanation

This activity is used to connect a maintenance program to a serial. If a valid active maintenance program is defined for the part number and revision of the serial, you need to connect the maintenance program to the serial before you can set the serial to either the In Operation or Out Of Operation status for the first time.

If access control is established for parts and serials, you can only work with the serials to which you are granted access. Likewise, if access control is established for maintenance programs, you can only view and connect the maintenance programs to which you have access. Access control is established by setting up access groups with valid users and assigning the applicable access group to the part or maintenance program to which access should be restricted.

Prerequisites

System Effects

As a result of this activity, the maintenance program is connected to the serial on which it will be performed.

Window

Serial Structure Information
Serial Structures
Serials
Vehicles
Define Maintenance Program

Related Window Descriptions

Change Maintenance Program On Serial - Step 1 of 2
Update values for interval maintenance on given serial - Step 2 of 2
Serial Structure Information
Serial Structure Information/Consist Of
Serial Structure Information/Multilevel  
Serial Structures
Serials
Vehicles
Define Maintenance Program/Affected Serials

Procedure

Follow this procedure to connect a maintenance program to a serial that is in the Planned For Operation status:

  1. Open the Serial Structure Information window or the Serials window.
  2. Populate (F2) or query (F3) for the necessary serial.
  3. Click the General tab if you are working in the Serial Structure Information window.
  4. In the Maint Program field, enter the maintenance program for the serial. Use the List of Values to select a valid value.
  5. Save the information (F12).

Follow this procedure to connect a maintenance program to a serial by using the Change Maintenance Program On Serial assistant:

  1. Open any one of the following windows or tabs depending on your work flow:
  1. Populate (F2) or query (F3) for the necessary serial.
  2. Right-click and click Change Maintenance Program. The Change Maintenance Program On Serial assistant opens.
  3. In the New Maint. Prog field, enter the ID of the maintenance program you want to connect to the serial. Click List to select a valid value.
  4. If you want to change the maintenance group of the serial, click List in the New Maint Group field to select and enter the new maintenance group for the serial.
  5. Select the Change maintenance program for all serials in structure check box if you want to update all serials in the structure with the new maintenance program.
  6. Select the Change maintenance group for all serials in the structure check box if you want to update all serials in the structure with the new maintenance group.
  7. Click Next.
  8. In the Update values for interval maintenance on given serial assistant step you can enter or change the start values for the interval maintenance of a serial(s) in the structure. This is useful for instance when the intervals for the maintenance code on the old maintenance plan are different to the intervals on the new maintenance plan and it is necessary to adjust the interval maintenance values accordingly. The upper table displays the interval maintenance for the primary operational parameters while the lower table displays all secondary operational parameters corresponding to the primary operational parameters.
  9. In the Value at Maintenance field, enter or change the total operational value for the part and serial number for which you want to change interval maintenance values. Note: The following conditions apply:
  1. In the Value Total field, enter the total operational value of the serial at the date of maintenance.
  2. Click Save to save your changes.
  3. Click Finish to close the assistant.

Follow this procedure to connect a valid active maintenance program to one or more affected serials:

  1. Open the Define Maintenance Program window.
  2. Populate (F2) or query (F3) for the active maintenance program.
  3. Click the Affected Serials tab to view all serials affected by this maintenance program.
  4. Select the serial record, right-click and then click Set Maintenance Program.
  5. Verify that the connected maintenance program is shown in the Maint Program ID, Maint Program Revision and Maint Program Description fields for the serial record.